My iLO interface has been attacked and it is being used for malicious purposes. I need to upgrade the firmware. The iLO web interface allows me to upload a.bin file ('Obtain the firmware image (.bin) file from the Online ROM Flash Component for HP Integrated Lights-Out.' ) Where can I find this.bin. Latest HP ILO firmwares. Here you can download the most recent HP iLO (Integrated Lights-Out) firmware files I could find on the HP’s website. ILO 3(Integrated Lights-Out 3) 펌웨어 버전이 1.26(또는 그 이하)인 HP 프로라이언트 서버의 전원이 꺼지는 동안 iLO 3 전력계가 최소 전력을 65535W로 잘못 표시할 수도 있습니다. Hardware platforms affected: HP Integrated Lights-Out 3 (iLO 3) Firmware for ProLiant G7 Servers, HP ProLiant BL2x220c.

HomeSwitchboardUnix AdministrationRed HatTCP/IP NetworksNeoliberalismToxic Managers
May the source be with you, but remember the KISS principle ;-)
Skepticism and critical thinking is not panacea, but can help to understand the world better
NewsHP ServersRecommended LinksCommand line interfaceILO3 TCP ports Firmware upgrade
Initial setupFiasco: some additional informationFiasco: some preliminary recommendationsRebooting the iLO 'Remote Console - in use' ProblemSerial console
SecurityUsing ILO virtual floppy drive for holding YAST autoyast installation file How do I reset the HP iLO IP address and passwordDell DRAC
Sysadmin Horror StoriesAdministration of Remote ServersHP Smart Array P410 controllerHumorRandom FindingsEtc

Introduction

The defining feature of ILO3 in versions up to and including 1.26 is its instability. It is unsafe to use with any product, but especially with large HP servers and blades. The first usable version of ILO 3 is 1.85 (CP026424.scexe) released May 13, 2015, long after server of V7 series became obsolete.

If ILO hangs and lose network connectivity for no obvious reasons, there is no reset button for ILO: you need to power server down, disconnect cables (or remove the blade) and power it up again. Sometimes the console can't connect tot he server/blade and only button and lights icon at the bottom of the screen are active. Sometimes it also loses time/date.

Blades are the most annoying case as there are usually way too many of them. But ILO freezing in remote production rack servers is nothing short of HP-made disaster. You need to shutting down, remove power cables and then reboot server such as DL580 or DL 380 to restore ILO functionality. Imagine the case when a remote site has no night shift personnel or there is no qualified personnel on the site at all and situation does not look too promising. In any case few would argue that HP managed to invent a very interesting engineering solution for the problem of fixing a crash or freezing of a small supplementary computer by shutting down the main production server and removing power cable. My sincere congratulations to HP team. You are the best ;-)

Notes:

  • Sometimes you can restore ILO functionality via RBSU (interface to ILO which is provided during boot ). But this is possible only if there is a person on site.
  • In case of blades you often do not even need to pull and reinsert the blade. CLI command in Onboard Administrator Firmware 1.30 and later have the command that permit to cut power to specific blade for 3 seconds. You need to connect via Telnet of ssh and to the enclosure if you can, then you just execute command

    The XX represents the Bay where the blade is located in. The command prompt you to confirm the action. Entering anything other than 'YES ' will result in the command not executing.

    Resetting the server causes the E-Fuse to be tripped causing all power to be momentarily removed from the server. Do you want to continue ? YES

Instability of a new version of a complex product (although overcomplexity of ILO is a blunder and has no excuse) is nothing new, but what make this problem a real disaster is absence of any convenient means of rebooting ILO without removing power cords from the box. And this is a real engineering fiasco. After three of four such operations with DL580 or with multiple blades at night you start passionately hate HP and its server products :-)

Instability of a new version of a complex product (although overcomplexity of ILO is a blunder and has no excuse) is nothing new, but what make this problem a real disaster is absence of any convenient means of rebooting ILO without removing power cords from the box.And this is a real engineering fiasco. After three of four such operations with DL580 or with multiple blades at night you start passionately hate HP and its server products :-)

Note: Version 1.65 was released November 26, 2013. It has better stability and I did not experienced this freezing situation with it yet.

Documentation looks like a translation from some foreign language into English ;-)

Seasoned sysadmin do not expect from vendor documentation much. We are trained to work with manuals written by people who do not understand the product and do not care, but in this area HP still stands out.

For exampleHP ProLiant Integrated Lights-Out 3 v 1.20 User Guide (HP part number 616301-003) in places looks like translation from some other language to English, which is an innovative trend, I would say a real breakthrough, for a large US company. As a result some quotes can well be submitted to the Onion (p. 85)

To use a physical CD/DVD-ROM drive in your client PC:
1. Select IRC within the Remote Console section. --[There is no IRC section in Remote control section]
2. Select the Virtual Drive tab --[There is no Virtual tab section]

and then select the drive letter of the desired physical CD/DVD-ROM --[There is no drop-menu with drive letters to select from] drive on your client PC from the drop-down menu.

The trick to understand this paragraph is that they are talking about a tab named 'Virtual drive' on the remote console screen, not about Remote console/Remote console section of ILO3 main menu :-). Please note that there is no IRC tab on remote console screen either, only 'Virtual drive' tab.

Another interesting tidbit is that ILO timeouts no matter what setting you put at Administration/Access/settings. So it takes your current setting for advisory and then does not follow up :-). If you installing OS on a remote server that might have an interesting effect on your mood as logout persistently resets virtual CD/DVD and virtual floppy drive. I agree that it provide an excellent security of this feature in a sense of making it impossible to use. As we all agree that security is important, that well might be implicit HP design goal, although just dropping this feature would be an equally secure and less frustrating solution. .

Additional cost of remote console

HP servers are more expensive then servers of competitors, such as Dell. So it is naturally to expect from them more. And HP does include ILO in all of its servers by default; so it's cost is implicitly reflected in the price if, for example you compare the cost of HP server and equivalent Dell server.

But at some point HP brass became way too greedy and decided to 'correct' this situation. The method they found is pretty interesting.

Unlike Dell DRAC, remote console capabilities are not free. HP demands additional license fee (around $300 for license with one year support) for the ability to use remote console with iLO 3. In view of those 'disconnects' that ILO 3 suffer from, I think HP need to pay users instead until they fix the problem :-).

In any case the price structure HP adopted is somewhat questionable. IMHO there should not be software license as this is a specialized appliance, not a general purpose device. To charge $300 for advanced license which nothing more than the ability to use remote console (based on VNC) does not look like a sophisticated business model.

For example Dell charges for hardware (Drac card) which is more logical: $99 for iDRAC6 express hardware, $349 hardware with enterprise version installed and $448 for version with 8GB SD card (this is 2011 prices without corporate discount). As we see the price of the device is suspiciously close to the price of the advanced license.

And DRAC actually provides some functionality that ILO currently does not have as the flash card size is enough for putting DVD image into it and that allow you to avoid a slow connection problems when booting the server from the image. DRAC the ability to send SMTP alerts. And the ability to send email alerts directly to sysadmin has great value in a typical enterprise environment if we take into account the amount of red type necessary for accomplishing the same via monitoring system such asHP Operations Manager.

Unfortunately it looks like Dell with DRAC 7 got into the same tar pit as HP. It also hangs.

ILO virtual DVD capabilities

They are really useful for booking an OS. But ILO virtual DVD capabilities are not very stable due to timeouts and usable mostly for booting installer (after that you can get ISO image from a nearby server via FTP or HTTP).

Beware of using 60 days free advanced ILO license

This is another funny (or not so funny) idiosyncrasy: you can get 60 days free advanced ILO license from HP, but the problem is that when you buy a permanent license, unless this is a license for multiple servers you can't replace temporary license with permanent (at least as of version 1.25; I know because I tried... ).

Over-engineered means unsecure

It looks like ILO3 is over-engineered and those who design and wrote the code have no or little clue how this hardware device is used in real world. That means that it represents one huge security hole, a hidden gateway to your servers. In additional to those that I mentioned there are known issues, related to certificate handling.

Judging from the experience with using ILO 3 I have little doubt that there are multiple exploits for each version of the device. That makes it a very attractive target for state-supported hackers as in most corporation ILO are not well protected and this vector of attack is typically overlooked.

From the security standpoint ILO 3 represents a hidden backdoor to your server for state-supported hackers. Nothing more, nothing less.

As such it should be secured by using a separate protected by firewall segment. For remote installations usage of VPN should be considered. Which of course means additional cost and complexity.

But please don't overlook this vector of attack. Due to overcomplexity of the codebase, state-supported hackers can breach built-in security as easy as knife enters the butter. If you need to protect corporate assets from this type of hackers in no way you can rely on built-in security features.

Instability Fiasco: some additional information

Versions up to 1.26 demonstrates is a very interesting type of instability. Often if you work with ILO long enough it logs you out. Or you can be logged out due to inactivity, and in early versions (probably up to 1.28) change of inactivity period was disregarded.

After that often you can't log-in again no matter how hard you try without shutting down the server, disconnecting power from the server and rebooting it. In other words under some mysterious circumstances such a log out also frequently switches ILO to a state in which it is not possible to connect to ILO's network port. It remains to visible to nmap:

Inability to connect to the iLO is unacceptable for the product the sole role of which provide ability to control server when something went wrong. This is fiasco or SNAFU in army terms.

Up to version 1.28 the most typical scenario of getting into this state is to let ILO login to timeout and close browser session with it. Here is the trace of what is happening:

As we mentioned before, the problem with such behavior is that if this is a remote installation with no local support personnel you are royally f*@$ed ;-).

Note:for HP blades ILO 3 was and still is (as of March 2012 or version 1.28) a disaster. It is unstable and often lock you out if you forget to logoff and timeout kicks in.

Resolution of HO ILO3 fiasco: some preliminary recommendations

Here are some preliminary recommendations:

  1. The first really usable version of ILO 3 is 1.85 (CP026424.scexe) released May 13, 2015, long after server of V7 series became obsolete. All versions before it including 1.82 (released Jan, 2015) are crap. As of September 2915 this firmware remains a free download from HP site and does not depend whether you have active support contract with HP or not (Bios firmware now requires contract)
  2. Version 1.65 of firmware os another version that is more or less OK (see Firmware upgrade for details). It looks like it fixes possible random server shutdowns problem.

    Looks like this upgrade solves the problem of instability (actually all versions starting from 1.28 were an improvement in comparison with really horrible previous versions).

    Still on blades you usually can't install it from the SCEXE file. HP recommendation

    To update firmware from the Linux operating system on target server:
    Download the SCEXE file to the target server.

    is bogus. Installation freezes with message '

    but it does not destroy the flash ROM. You can still reboot ILO and do it via remote interface
    Never try to execute recommended by HP command sh CP016203.scexeon blades. It might fail and then what?
    I would like to stress it again that the message:

    can be displayed for a long time and then the process timeout:

    For blades the only reliable way to upgrade firmware is to download the SCEXE file to a client running a Linux operating system. Execute:

    This command will unpack the iLO3 bin into a user specified 'directory'. If the directory does not exist, the unpacker will attempt to create it. Then move.binfile to your windows client and do upgrade from ILO Web interface. See Uploading .bin file via ILO3 Web interface

    For blades the only reliable way is Download the SCEXE file to a client running a Linux operating system. Execute:

    This command will unpack the iLO3 bin into a user specified 'directory'. If the directory does not exist, the unpacker will attempt to create it. Then move.binfile to your windows client and do upgrade from ILO Web interface. See Uploading .bin file via ILO3 Web interface

  3. On the first login create at least one other user account in addition to Administrator account. Multiple account make the 'sudden freeze' problem less frequent in versions up to 1.26. The highest frequency observed is when there is only one account (Administrator).
  4. In Administration/Access setting screen set 'Idle connection Timeout drop-down list to 'Indefinite'. Go to the Administration/Network tab and click apply. I think this setting is activated only on reboot of ILO, while new user setting does not require reboot. This is really Byzantine peace of equipment.
  5. Logout explicitly as you finished using ILO.

Initial setup

  1. Restart or power the server on (Important: only removing power from power supplies resets ILO).

  2. Press the F8 key when ILO prompt appears during POST.

  3. Select Network>DNS/DHCP, press the Enter key, and then select DHCP Enable. Press the spacebar to turn off DHCP. Be sure that DHCP Enable is set to Off, and save the changes.

  4. Select Network>NIC>TCP/IP, press the Enter key, and enter the appropriate information in the IP Address, Subnet Mask, and Gateway IP Address fields.

  5. Save the changes.

  6. Additional recommended settings:
    • Idle connection timeout (minutes) -- infinite
    • Require Login for iLO RBSU -- Disabled.
    • Serial Command Line Interface Status - Enabled - No Authentication

Applying firmware upgrade

In the first half of 2011 HP released iLO firmware updates one each second month or so. Later it became more rare but still it creates significant load on the sysadmins, as if they have nothing to do but upgrade produced by HP junk each second month. Such cavalier attitude toward important part of their server undermines any trust in HP engineering abilities.

You can use iLO Online updates for Windows and linux. Packages have different extensions (.exe for Windows and .scexe for Linux). Update can be applied in two ways:

  • Running executable on the server. Does not always work but if works this is the fastest method. Typically this method works OK only for standalone DL servers:
  • Uploading .bin file via ILO3 Web interface. This option to update the iLO firmware requires .bin file that you need to extract first.
Since web based firmware update supports only the firmware image file (.BIN file) it is important not to forget to extract the .BIN file from the firmware package first. The .BIN firmware update file is not available as a direct download option at HP.com

Steps

  1. Download iLO online firmware update package
  2. Extract the .BIN file from it. For Linux .scexe file can be extracted using command: For example
  3. Load .bin file it into ILO using ILO browser

iLO Firmware update from USB drive

In case you screw things up you can use HP Smart Update Firmware DVD of the server to update the iLO firmware. To use HP Smart Update Manager on the Firmware Maintenance CD:

  • Get Firmware Maintenance CD Can be downloaded from Firmware Maintenance CD - HP Business Support Center
  • Place the that came with the server on a USB key using the USB Key Creator Utility.
    • HP USB Key Utility for Windows

      The HP USB Key Utility is a Windows application that will allow the user to copy the following CD contents to a USB memory key: HP SmartStart CD, HP Firmware Maintenance CD, HP Smart Update Firmware DVD, HP Easy Set-up CD. Users may then run the CD applications from a USB key instead of from the CD.
      Type: Utility - Tools

    • Version: 1.6.0.0 (5 Apr 2011) can be downloaded from
      http://h20000.www2.hp.com/bizsupport/TechSupport/SoftwareDescription.jsp?swItem=MTX-eee9b3632ced47478f9ef85d43&lang=en&cc=us&mode=3&
  • Copy CP015458.scexe to /hp/swpackages directory on the USB Key.
  • Follow HP Smart Update Manager steps to complete firmware update.

Rebooting the iLO

The blunders HP committed would be less biting if there were a possibility to reboot ILO separately from server using some hardware button. But there no such capability for stand-alone HP servers. Please note that there is such capability for blades not not for ILO alone, but together with the blade (see above).

HP communities this is a very interesting way:

You can reboot ILO

1) By removing all the power cables from the server.

2) By changing the system maintenance switch 1 on the system board (DL 580). That's convoluted operation:

Power the server OFF.
Disconnect the power cord from the server.
Remove the access panel.
Remove the controller and the riser board.
Push and hold the power button down for about a minute.
Remove and reseat all the memory DIMMS.
Disconnect and reconnect the VGA cable from the server.
Set the System maintenance switch 1 to the ON position.
Power the server back ON.
After the server has completed the Power-On Self Test, power the server OFF (If display is present).
Set the System maintenance switch 1 back to the OFF position.
Power the server back ON.

'Remote Console - in use' Problem

This is another annoying problem. In short sometime you can't connect to remote console getting the message 'Remote Console - in use'. But it is less severe then previous in recent versions as remote interface is still functional and you can reboot ILO from it:

  • iLO There does not appear to be an option within the ssh and Web interfaces of the iLO to reset the iLO and clear an 'in use' remote console connection. Select Administration, and then Network Settings. Click Apply, and iLO will reset, freeing the remote console.
  • iLO 2/ILO3. Two ways:
    • Select Diagnostics, and then click Reset under Reset Integrated Lights-Out 2.
    • Select Administration, and then Network. Click Apply, and iLO 2 will reset, freeing the remote console.

See alsoHow to reset iLO 2 (HP Integrated Lights-Out) of HP Proliant or ...

New features in iLO 3

Here is some info from readme for version 1.0:

The following features are new with iLO 3 v 1.00:

Faster performance:

  • Eight times faster remote console for optimal remote management performance

  • Three times faster Virtual Media for high performance remote deployments and updates

  • High-performance Microsoft Windows Integrated Remote Console

  • Full-featured Java Integrated Remote Console

  • 250 MHz iLO 3 processor

  • 128 MB ECC DDR iLO 3 memory

Streamlined interface:

  • Web 2.0 Interface using JSON technology
  • Remote Console Direct Access for immediate iLO 3 access to critical systems
Enhanced standards support:
  • IPMI 2.0 over LAN/DCMI support for simple server control in scale-out environments

  • AES Encryption in HW industrial strength security without performance impact

  • Simple Network Time Protocol support

Obsolete features

  • Telnet Interface (multiple SSH sessions are available for your use)

  • Terminal services pass-through (the iLO 3 Integrated Remote Console performance and feature set removes the need for this service)

  • Applet for the Virtual Serial Port (the Virtual Serial Port is still available through SSH)

  • Stand-alone applet for Virtual Media (the Virtual Media functionality is included in the Java IRC as well as the Windows IRC)

  • Remote Console Hot Keys (the IRC applications support real keyboard-like functions)

  • C-Class BladeSystem Wizard (the BladeSystem Onboard Administrator now provides the BladeSystem Wizard support)

Top Visited
Switchboard
Latest
Past week
Past month

NEWS CONTENTS

  • 20131212 : Advisory HP Integrated Lights-Out 3 and HP Integrated Lights-Out 4 - False CPU Overheating Messages May Be Logged ( Advisory HP Integrated Lights-Out 3 and HP Integrated Lights-Out 4 - False CPU Overheating Messages May Be Logged , Dec 12, 2013 )
  • 20131212 : Firmware update problem during remote update ( )
  • 20131212 : HP Integrated Lights-Out 3 Firmware upgrade version 1.5 ( HP Integrated Lights-Out 3 Firmware upgrade version 1.5, )
  • 20131212 : The Command Line Interface (CLI) Command to Create a New User May Not Function in iLO 3 Firmware Version 1.26 or Version 1.28 ( The Command Line Interface (CLI) Command to Create a New User May Not Function in iLO 3 Firmware Version 1.26 or Version 1.28 , )
  • 20121220 : Advisory (Revision) HP Integrated Lights-Out 3 (iLO 3) - The iLO 3 ROM-Based Setup Utility May Incorrectly Display the Gateway ( 12/10/2012 )
  • 20120625 : If an HP ProLiant Server Resets Unexpectedly, the Integrated Management Log (IML) Should Be Check ( If an HP ProLiant Server Resets Unexpectedly, the Integrated Management Log (IML) Should Be Check, Jun 25, 2012 )
  • 20120601 : Systematic failure during installation of version 1.29 on HP blades ( Jun 01, 2012 )
  • 20120515 : HP Integrated Lights-Out 3 (iLO 3) Version 1.25 (or Earlier) - iLO Virtual Media Service May Randomly Stop Responding When Attempting to Connect a Virtual Device in Remote Console ( HP Integrated Lights-Out 3 (iLO 3) Version 1.25 (or Earlier) - iLO Virtual Media Service May Randomly Stop Responding When Attempting to Connect a Virtual Device in Remote Console, May 15, 2012 )
  • 20120515 : Disabling an iLO 3 NIC May Cause the iLO 3 Link Status to be Incorrectly Displayed as Failed in HP System Management Homepage and HP Systems Insight Manager (HP SIM) ( Disabling an iLO 3 NIC May Cause the iLO 3 Link Status to be Incorrectly Displayed as Failed in HP System Management Homepage and HP Systems Insight Manager (HP SIM), May 15, 2012 )
  • 20120515 : iLO 3 Firmware Flash Progress May Intermittently Stop at One Percent or Take Sev ( iLO 3 Firmware Flash Progress May Intermittently Stop at One Percent or Take Sev, May 15, 2012 )
  • 20120507 : ILO3 FW 1.26-1.28 Drive Information Shows Only Physical Driver Stat ( ILO3 FW 1.26-1.28 Drive Information Shows Only Physical Driver Stat, May 07, 2012 )
  • 20120507 : Integrated Lights-Out 3 (iLO 3) FIRMWARE UPGRADE REQUIRED to Prevent Unexpected Server ( Integrated Lights-Out 3 (iLO 3) FIRMWARE UPGRADE REQUIRED to Prevent Unexpected Server, May 07, 2012 )
  • 20120507 : HP Integrated Lights-Out 3 Version 1.25 (or Earlier) Browser Interface and Secure Shell (SSH) May Stop Responding When Attempting to Login to SSH Using a Private SSH-DSA Key Larger Than 2048 Bits ( HP Integrated Lights-Out 3 Version 1.25 (or Earlier) Browser Interface and Secure Shell (SSH) May Stop Responding When Attempting to Login to SSH Using a Private SSH-DSA Key Larger Than 2048 Bits , May 07, 2012 )
  • 20120507 : HP Integrated Lights-Out 3 (iLO 3) - HP Proliant G7 Blade servers - iLO 3 Firmware version 1.25 Server Power On Issue Caused by Overprovisioning of Power ( HP Integrated Lights-Out 3 (iLO 3) - HP Proliant G7 Blade servers - iLO 3 Firmware version 1.25 Server Power On Issue Caused by Overprovisioning of Power , )
  • 20120507 : Advisory HP ProLiant Servers - Integrated Lights-Out 3 and 4 (iLO 3-iLO 4) User Guides Incorrectly State That New Certificate Is Always Created When iLO Is Reset ( 2012-04-30 )
  • 20120426 : HP Lights-Out XML PERL Scripting Sample for Linux (ver 4.00.0) ( HP Lights-Out XML PERL Scripting Sample for Linux (ver 4.00.0), Apr 26, 2012 )
  • 20120416 : Advisory: HP Integrated Lights-Out 3 (iLO 3) - The iLO 3 ROM-Based Setup Utility May Incorrectly Display the Gateway IP Address as 0.0.0.0 After Upgrading iLO 3 to Firmware Version 1.28 (c03283274) ( Advisory: HP Integrated Lights-Out 3 (iLO 3) - The iLO 3 ROM-Based Setup Utility May Incorrectly Display the Gateway IP Address as 0.0.0.0 After Upgrading iLO 3 to Firmware Version 1.28 (c03283274), Apr 16, 2012 )
  • 20120416 : Advisory ProLiant Servers Integrated Lights-Out 3 - FIRMWARE UPGRADE RECOMMENDED to Avoid Java and Internet Explorer Unrespon ( Sept 12, 2011 )
  • 20120102 : Connecting to HP iLO using the command line by Emerson Takahashi ( July 17, 2010 , setaOffice )
  • 20111101 : What TCP-IP ports does iLO 3 use ( Aug 10, 2010 , HP Communities )
  • 20111031 : c00257375 Best Practices for Integrated Lights-Out and Integrated Lights-Out 2, 3-rd edition ( HP )
  • 20111031 : Default Port for the remote console for iLO 3 ( HP Communities )
  • 20111031 : Opening firewall ports for iLO ( Aug.20, 2009 , NachoTech )
  • 20111012 : HP Integrated Lights-Out 3 Version: 1.26 (29 Aug 2011) ( HP Integrated Lights-Out 3 Version: 1.26 (29 Aug 2011), Oct 12, 2011 )
  • 20111011 : Reset ILO (Integrated Lights-Out 2) on HP Server ( Stracca Blog )
  • 20110306 : HP Integrated Lights-Out 3 (iLO 3) - Firmware CD Supplemental Update - Online ROM Flash Component for Linux ( HP Integrated Lights-Out 3 (iLO 3) - Firmware CD Supplemental Update - Online ROM Flash Component for Linux , Mar 6, 2011 )

Old News ;-)

[Dec 12, 2013]Advisory HP Integrated Lights-Out 3 and HP Integrated Lights-Out 4 - False CPU Overheating Messages May Be Logged

Any HP ProLiant G7 and Gen8 series servers configured with Intel processors; iLO 3 Firmware Version 1.61 (or earlier) and iLO 4 Firmware Version 1.30 (or earlier).

RESOLUTION

Hp Ilo 3 Firmware 1.26

To prevent the false messages from occurring, update the iLO firmware as follows:

Update the iLO 3 firmware to version 1.65 (or later):

Perform the following steps to obtain the latest iLO 3 firmware version:

  1. Click on the following link:
  2. Select the appropriate operating system.
  3. Click on 'Firmware - Lights-Out Management.'
  4. Locate, download, and install iLO 3 Firmware Version 1.65 (or later).

Update the iLO 4 firmware to version 1.32 (or later):

Perform the following steps to obtain the latest iLO 4 firmware version:

  1. Click on the following link:
  2. Select the appropriate operating system.
  3. Click on 'Firmware - Lights-Out Management.'
  4. Locate, download, and install iLO 4 Firmware Version 1.32 (or later).

Firmware update problem during remote update

If using HP SUM bundled in the HP Support Pack for ProLiant (SPP) in order to update the HP ProLiant iLO3 firmware from 1.2x to 1.50 remotely, the update will fail.

The installation will report as failed, and the HP SUM error log will show the following:

HP Smart Update Manager Installation Log Starting ILO firmware update. Initializing connection to ILO 192.168.10.1. Connection established to ILO. Checking the type of ILO. load -source http://192.168.10.20:63000/Rep1/cp016202/3.bin status=1 status_tag=COMMAND SPAWNED Mon Jan 14 11:33:27 2013 Attempting to load iLO3 firmware image. status=2 status_tag=COMMAND PROCESSING FAILED error_tag=COMMAND ERROR-UNSPECIFIED Mon Jan 14 11:33:27 2013 Unable to retrieve a valid iLO3 firmware image. Check file path and login credentials.

This issue is due to a bug in the iLO3 firmware.

HP SUM executes the load -source command from iLO3 SSH console, but when the iLO3 web pooler proceeds to download the firmware file, it will fail.

Therefore, it is an iLO3 issue and not with HP SUM.

This issue does not happen if running HP SUM locally, only when trying remote updates.

Solution

This issue does not occur in 1.1x or 1.50 and later firmware. llpadding='0' width='100%'> As a workaround, use the following options:
  1. Run the iLO3 firmware update locally on the server. The firmware will be transferred via the iLO3 driver.
  2. If need to update several systems remotely, use the iLO RIBCL XML scripts. Use the script Update_Firmware.xml as a template.

HP Integrated Lights-Out 3 Firmware upgrade version 1.5

In order to update iLO3 to 1.50, the iLO3 firmware must be in the 1.2x versions.
Type:Firmware - Lights-Out Management
Version:1.50 (26 Oct 2012)
Operating System(s):Red Hat Enterprise Linux 5 Desktop (x86), Red Hat Enterprise Linux 5 Desktop (x86-64), Red Hat Enterprise Linux 5 Server (x86), Red Hat Enterprise Linux 5 Server (x86-64), Red Hat Enterprise Linux 6 Server (x86), Red Hat Enterprise Linux 6 Server (x86-64), SUSE Linux Enterprise Server 10 (AMD64/EM64T), SUSE Linux Enterprise Server 10 (x86), SUSE Linux Enterprise Server 11 (AMD64/EM64T), SUSE Linux Enterprise Server 11 (x86), VMware ESX/ESXi 4.0, VMware ESX/ESXi Server 3.5

The Command Line Interface (CLI) Command to Create a New User May Not Function in iLO 3 Firmware Version 1.26 or Version 1.28

SUPPORT COMMUNICATION - CUSTOMER ADVISORY
Document ID: c03573824

Version: 1

Advisory: HP Integrated Lights-Out 3 (iLO 3) - The Command Line Interface (CLI) Command to Create a New User May Not Function in iLO 3 Firmware Version 1.26 or Version 1.28
NOTICE: The information in this document, including products and software versions, is current as of the Release Date. This document is subject to change without notice.
Release Date: 2012-11-14

Last Updated: 2012-11-14

[ Dec 20, 2012 ] Advisory (Revision) HP Integrated Lights-Out 3 (iLO 3) - The iLO 3 ROM-Based Setup Utility May Incorrectly Display the Gateway

Solution is to upgrade to version 1.5 (October 2012)
12/10/2012

After upgrading HP Integrated Lights-Out 3 (iLO 3) Firmware to Version 1.28 and using the iLO 3 ROM-Based Setup Utility (RBSU) to configure a static IP address using the following steps, the next time that the iLO 3 RBSU Setup Utility is loaded, the iLO 3 Gateway IP address may be incorrectly displayed as 0.0.0.0. This is a 'display only' issue in iLO 3 Firmware Version 1.28. No other iLO 3 Firmware versions are affected.

The condition occurs after performing the following steps:

Restart or power on the server. Press the F8 key when prompted during POST. The iLO 3 RBSU runs. Select Network > DNS/DHCP, press the ENTER key, and then select DHCP Enable . Press the spacebar to turn off DHCP. Be sure that DHCP Enable is set to Off, and save the changes. Select Network > NIC > TCP/IP, press the ENTER key, and enter the appropriate information in the IP Address, Subnet Mask, and Gateway IP Address fields. Save the changes. Exit iLO 3 RBSU. The change takes effect after exiting iLO 3 RBSU. SCOPE Any ProLiant server configuration using HP Integrated Lights-Out 3 (iLO 3) Firmware Version 1.28.

RESOLUTION This is a display only issue and can be safely ignored.

HP Integrated Lights-Out 3 (iLO 3) Firmware Version 1.50 (or later) corrects the Gateway IP Address display issue. To access the HP Integrated Lights-Out 3 (iLO 3) driver and software download page, click on the following URL:

OR

As a workaround, use the iLO 3 web GUI to verify that the Gateway IP address is displaying correctly on the network. The network settings can be checked by looking under Administrator -> Network.

[Jun 25, 2012]If an HP ProLiant Server Resets Unexpectedly, the Integrated Management Log (IML) Should Be Check

Document ID: c03370645

Version: 1

Notice: HP ProLiant Servers - If an HP ProLiant Server Resets Unexpectedly, the Integrated Management Log (IML) Should Be Checked to Determine if the Source of the Reset Is Indicated

NOTICE: The information in this document, including products and software versions, is current as of the Release Date. This document is subject to change without notice.

Release Date: 2012-06-12

Last Updated: 2012-06-12

DESCRIPTION

If an HP ProLiant server resets unexpectedly, the Integrated Management Log (IML) should be checked to determine if the source of the reset is indicated. This information can help determine if any action needs to be taken.

The Integrated Management Log (IML) records hardware events and stores them in a formatted table. It records the time of the event and categorizes events in severity levels such as:

  • Critical
  • Caution
  • Repaired
  • Status
DETAILS

There are numerous conditions that can result in a server unexpectedly resetting. Whenever such a reset occurs, the Integrated Management Log (IML) should be checked to determine if the cause of the reset is indicated. While the IML will not always indicate the cause of an unexpected reset, it will in most cases.

The IML can be viewed from the HP Integrated Lights-Out (iLO) web page or using other HP Management Tools. Some of the most commonly used methods are:

IML Viewer:

  1. Click Start->All Programs -> HP System Tools-> HP ProLiant Integrated Management Log Viewer.
  2. The IML Viewer will open and the IML logs will be displayed on the screen.

From HP Integrated Lights-Out (iLO):

  1. Open the iLO web interface.
  2. Enter the iLO Login name and Password.
  3. From the left menu, access IML Logs .

From the System Management Homepage (SMH):

  1. Click Start-> All Programs -> HP Management Agents -> HP System Management Homepage.
  2. Click on Logs . The log screen will be displayed.
  3. Click on Integrated Management Log .

[Jun 01, 2012] Systematic failure during installation of version 1.29 on HP blades

Only blades are affected. Standalone servers like , DL360, DL380, DL580 are OK.

[May 15, 2012]HP Integrated Lights-Out 3 (iLO 3) Version 1.25 (or Earlier) - iLO Virtual Media Service May Randomly Stop Responding When Attempting to Connect a Virtual Device in Remote Console

c03316654

Hp Ilo 2 Firmware Upgrade

Products: HP ProLiant DL Servers, HP ProLiant BL Server Blades, HP ProLiant Scalable Systems, Insight Control Software, HP ProLiant ML Servers

Description: iLO Virtual Media Service May Randomly Stop Responding When Attempting to Connect a Virtual Device in Remote Console

[May 15, 2012]Disabling an iLO 3 NIC May Cause the iLO 3 Link Status to be Incorrectly Displayed as Failed in HP System Management Homepage and HP Systems Insight Manager (HP SIM)

c03327392

Products: Software, ProLiant Servers, BladeSystem

Description: Advisory: HP Integrated Lights-Out 3 (iLO 3) - Disabling an iLO 3 NIC May Cause the iLO 3 Link Status to be Incorrectly Displayed as Failed in HP System Management Homepage and HP Systems Insight Manager (HP SIM)

[May 15, 2012]iLO 3 Firmware Flash Progress May Intermittently Stop at One Percent or Take Sev

Document ID: c03318935

Version: 1

Advisory: HP Integrated Lights-Out 3 (iLO 3) - iLO 3 Firmware Flash Progress May Intermittently Stop at One Percent or Take Several Hours to Complete

NOTICE: The information in this document, including products and software versions, is current as of the Release Date. This document is subject to change without notice.

Release Date: 2012-05-07

Last Updated: 2012-05-07

DESCRIPTION

While upgrading the HP Integrated Lights-Out 3 (iLO 3) from any previous version prior to version 1.28 (or later), the firmware flash progress may intermittently stop at one percent or take several hours to complete. This occurs due to idle Secure Shell (SSH) connections that are incorrectly closed and then time-out, causing the iLO 3 CPU to become busy and stall or delay the firmware flash progress.

An error in the way SSH sessions are shut down causes iLO 3 to assume that the sessions are fully active and constantly transferring data, delaying the firmware flash progress. HP Systems Insight Manager (HP SIM) servers and other SSH management tools located on the same network as iLO 3 may open these SSH connections.

SCOPE

Any HP ProLiant server with Integrated Lights-Out 3 (iLO 3) Firmware Version 1.26 (or earlier).

RESOLUTION

This is resolved by upgrading Integrated Lights-Out 3 (iLO 3) to firmware version 1.28 (or later).

Note : The issue may occur while upgrading to version 1.28 (or later) if upgrading from a version of the firmware prior to version 1.28.

Until the firmware upgrade is installed, reset iLO 3 to clear the SSH connection state prior to flashing the firmware.

If the firmware flash progress has stopped, connect several simultaneous SSH sessions until no additional SSH connections are allowed. Then close them normally to reset the connection state and allow the flash progress to continue.

Perform the following steps to obtain the latest iLO 3 firmware version:

  1. Click on the following link:
  2. Select the appropriate operating system.
  3. Click 'Firmware - Lights-Out Management.'
  4. Locate, download, and install iLO 3 Firmware Version 1.28 (or later).

[May 07, 2012]ILO3 FW 1.26-1.28 Drive Information Shows Only Physical Driver Stat

For ILO3 with firmware 1.26 and 1.28, web GUI and CLI does not show rebuilding status for Drive information .

Web GUI and CLI show only OK or Not installed .

[May 07, 2012]Integrated Lights-Out 3 (iLO 3) FIRMWARE UPGRADE REQUIRED to Prevent Unexpected Server

IMPORTANT : The Integrated Lights-Out 3 (iLO 3) firmware upgrade provided in the Resolution is required to prevent unexpected shutdowns, false CPU clock throttled messages, or incorrect values displayed via the PPIC command. HP recommends performing this upgrade at the customer's earliest possible convenience. Neglecting to perform the recommended iLO 3 firmware upgrade could result in the potential for subsequent errors to occur.

On an HP ProLiant SL390s G7 server, after upgrading the Integrated Lights-Out 3 (iLO 3) firmware to version 1.26, the server may experience unexpected shutdowns, false CPU clock throttled messages displayed in the operating system console, or incorrect values displayed via the ProLiant Power Interface Configuration (PPIC) command.

SCOPE
Any HP ProLiant SL390s G7 server (2U or 4U) after upgrading the Integrated Lights-Out 3 (iLO 3) firmware to version 1.26.

RESOLUTION
To prevent these issues from occurring, upgrade the Integrated Lights-Out 3 (iLO 3) to Firmware Version 1.28 (or later).

[May 07, 2012] HP Integrated Lights-Out 3 Version 1.25 (or Earlier) Browser Interface and Secure Shell (SSH) May Stop Responding When Attempting to Login to SSH Using a Private SSH-DSA Key Larger Than 2048 Bits

May 03 2012 | c03315526

Products: HP ProLiant BL Server Blades, Insight Control Software

Description: Advisory: HP BladeSystem ProLiant Server Blades - HP Integrated Lights-Out 3 Version 1.25 (or Earlier) Browser Interface and Secure Shell (SSH) May Stop Responding When Attempting to Login to SSH Using a Private SSH-DSA Key Larger Than 2048 Bits

HP Integrated Lights-Out 3 (iLO 3) - HP Proliant G7 Blade servers - iLO 3 Firmware version 1.25 Server Power On Issue Caused by Overprovisioning of Power

Resolution is to apply firmware version 1.26.

HP Proliant G7 Blade servers might exibit the issue where these servers are not powering On by default any longer when they have HP iLO firmare 1.25 applied.

The issue is that with iLO 3 firmware 1.25 some half height HP Proliant Blade servers get assigned 509 W of power and full height servers get 1800 W of power assigned. Sometimes, it is on an average of 60% more then what it should be.

See the screenshot below for visual indicator...

[May 07, 2012]Advisory HP ProLiant Servers - Integrated Lights-Out 3 and 4 (iLO 3-iLO 4) User Guides Incorrectly State That New Certificate Is Always Created When iLO Is Reset

2012-04-30

The HP Integrated Lights-Out 3 and 4 (iLO 3/iLO 4) User Guides incorrectly state that a new certificate is always created each time that iLO is reset (Diagnostics -> reset on iLO). For example, the iLO 3 Version 1.20 User Guide states the following on page 166:

If the iLO 3 self-signed certificate is installed permanently into some browsers and the iLO 3 is reset, you might not be able to log back in to iLO 3 because iLO 3 generates a new self-signed certificate every time it is reset.

HP ProLiant Integrated Lights-Out 3 Version 1.20 User Guide
http://h20000.www2.hp.com/bc/docs/support/SupportManual/c02774507/c02774507.pdf

Any HP ProLiant server with Integrated Lights-Out 3 or 4 (iLO 3/iLO 4)

[Apr 26, 2012]HP Lights-Out XML PERL Scripting Sample for Linux (ver 4.00.0)

Products: BladeSystem, Options and Accessories, ProLiant Servers, Software

OS: Other Legacy OS,Linux

Description: This is a set of sample XML scripts used to manage the configuration of Integrated Lights-Out (iLO) management processors and to control servers in which iLO devices are in use. Use LOCFG.PL (available in this bundle) to run the XML.

[Apr 16, 2012]Advisory: HP Integrated Lights-Out 3 (iLO 3) - The iLO 3 ROM-Based Setup Utility May Incorrectly Display the Gateway IP Address as 0.0.0.0 After Upgrading iLO 3 to Firmware Version 1.28 (c03283274)

Products: HP ProLiant DL Servers, HP ProLiant BL Server Blades, HP ProLiant ML Servers, HP ProLiant Scalable Systems, Insight Control Software

Description: Advisory: HP Integrated Lights-Out 3 (iLO 3) - The iLO 3 ROM-Based Setup Utility May Incorrectly Display the Gateway IP Address as 0.0.0.0 After Upgrading iLO 3 to Firmware Version 1.28

Advisory ProLiant Servers Integrated Lights-Out 3 - FIRMWARE UPGRADE RECOMMENDED to Avoid Java and Internet Explorer Unrespon

Sept 12, 2011

IMPORTANT : The Integrated Lights-Out 3 firmware upgrade provided in the Resolution is recommended to prevent Java and Internet Explorer from becoming unresponsive when attempting to acquire an already open Integrated Lights-Out 3 Remote Console session by opening the Java Remote Console applet. HP recommends performing this upgrade at the customer's earliest possible convenience. Neglecting to perform the recommended action and not performing the recommended resolution could result in the potential for subsequent errors to occur.

Attempting to acquire an already open Integrated Lights-Out 3 (iLO 3) Remote Console session by opening the Java Remote Console applet may cause Java and Internet Explorer to stop responding when running iLO 3 firmware version 1.20 (or earlier).

Any ProLiant server with Integrated Lights-Out 3 Version 1.20 (or earlier).

[Jan 02, 2012]Connecting to HP iLO using the command line by Emerson Takahashi

July 17, 2010 | setaOffice

Just ssh to the IP that you configured the iLO

emerson@shellcore:~ $ ssh emerson@192.168.50.118
emerson@192.168.50.118′s password:
User:Emerson Takahashi logged-in to ILO_TESTLABHP.(192.168.50.118)
iLO 2 Advanced Evaluation 1.81 at 11:05:47 Jan 15 2010
Server Name: proliant_g5
Server Power: On

hpiLO->

Since I will access through a text terminal, Linux is configured to use the serial port (configured through the file /boot/grub/grub.conf)

hpiLO-> help
status=0
status_tag=COMMAND COMPLETED

DMTF SMASH CLP Commands:

help : Used to get context sensitive help.
show : Used to show values of a property or contents of a collection target.
create : Used to create new user account in the name space of the MAP.
Example: create /map1/accounts1 username= password=
name=
group=

delete : Used to delete user account in the name space of the MAP.
Example: delete /map1/accounts1/

load : Used to move a binary image from an URL to the MAP. The URL is
limited to 80 characters
Example : load -source http://192.168.1.1/images/fw/iLO2_130.bin

reset : Used to cause a target to cycle from enabled to disabled and back to enabled.

set : Used to set a property or set of properties to a specific value.
start : Used to cause a target to change state to a higher run level.
stop : Used to cause a target to change state to a lower run level.
cd : Used to set the current default target.
Example: cd targetname

exit : Used to terminate the CLP session.
version : Used to query the version of the CLP implementation or other CLP
elements.

oemhp_ping : Used to determine if an IP address is reachable from this iLO 2.
Example : oemhp_ping 192.168.1.1 , where 192.168.1.1 is the IP address that you wish
to ping

oemhp_loadSSHKey : Used to authorize a SSH Key File from an URL The URL is
limited to 80 characters
Example : oemhp_loadSSHKey -source http://UserName:password@192.168.1.1/images/SSHkey1.ppk

HP CLI Commands:

POWER : Control server power.
UID : Control Unit-ID light.
NMI : Generate an NMI.
VM : Virtual media commands.
VSP : Invoke virtual serial port.

Type VSP and you're in. To login as root you need to include the serial port (in this case ttyS1) on your /etc/securetty file or you will be given the error message that your user or password is wrong.

hpiLO-> VSP

Starting virtual serial port.
Press 'ESC (' to return to the CLI Session.

hpiLO-> Virtual Serial Port active: IO=0x02F8 INT=3

login as:

[Nov 01, 2011]What TCP-IP ports does iLO 3 use

Aug 10, 2010 | HP Communities

You can look up what ports are used via the iLO 3 web interface. Expand the 'Administration' menu on the left, then click on the 'Access Settings' link. That screen will tell you the ports used by the various services.

Here are the defaults:
SSH 22
Web (non-SSL) 80
SSL 443
IPMI-over-LAN 623
Remote Console 17990
Virtual Media 17988

You might also need to enable other ports if you're using DHCP, DNS, SNTP, SNMP, and/or LDAP from iLO.

[Oct 31, 2011]c00257375 Best Practices for Integrated Lights-Out and Integrated Lights-Out 2, 3-rd edition

HP

For an iLO device to work properly when going across routers using port blocking and/or firewalls, ports 23, 80, 443, and 17988 must be open.

The directory services LDAP port (636) may be required. The Terminal Services RDP port (3389) may be required.

Port 23 is for the Telnet ports where the remote and graphical Remote Console is used, port 80 is for HTTP communications, port 443 is required for the HTTPS connection, and port 17988 is for Virtual Media.

LDAP traffic from a directory server uses random port numbers to enter the iLO device.

The inability to access the iLO management ports is often confused with incorrect proxy settings. When in doubt, disable proxy in Internet Explorer or Netscape.

[Oct 31, 2011]Default Port for the remote console for iLO 3

HP Communities

Hi Guys,

We have found that the remote console port defined for iLo3 has changed from being 3389 (standard RDP port) to 17990.

Can one of you please ask HP about the reasoning about this change and if it will be an issue if we change this to the standard 3389 port. The alternative is that we get NS to open the port 17990 on the firewall then we do not have to manually change every iLO 3 interface for servers in ecom.

***************************

David responded:

**************************

I think they're confusing 2 different things. Port #3389 is a standard RDP port and was valid for the 'iLO Terminal Services Pass-through' but never was the port for accessing the iLO remote console. Since TS Pass-through is no longer available with iLO3, this doesn't apply.

[Oct 31, 2011] Opening firewall ports for iLO

Aug.20, 2009 | NachoTech

If you want to access an iLO behind a firewall, there are some TCP ports that need to be opened on the firewall to allow all iLO traffic to flow through. Here is a list of the default ports used by iLO, but these can be modified on iLO's Administration… Access… Services… tab.

[Oct 12, 2011]HP Integrated Lights-Out 3 Version: 1.26 (29 Aug 2011)

Installation:

To update firmware from the Linux operating system on target server:
Download the SCEXE file to the target server. Execute: sh CP015458.scexe

To obtain firmware image for updating via iLO user interface, utilities, or scripting interface:
Download the SCEXE file to a client running a Linux operating system. Execute: sh CP015458.scexe --unpack=directory.

This command will unpack the iLO3 bin into a user specified 'directory'. If the directory does not exist, the unpacker will attempt to create it.

To use HP Smart Update Manager on the Firmware Maintenance CD:

  • Place the Firmware Maintenance CD on a USB key using the USB Key Creator Utility.
  • Copy CP015458.scexe to /hp/swpackages directory on the USB Key.
  • Follow HP Smart Update Manager steps to complete firmware update.

[Oct 11, 2011] Reset ILO (Integrated Lights-Out 2) on HP Server

Stracca Blog

Recently I had the necessity to reset the ILO interface of an HP Proliant Server.
I found that you need to connect in ssh (or in telnet) to do it.
One connect give this commands:

cd /Map1
reset

Here an example:

User:admin logged-in to ILOGB87451B7E(10.1.1.15)
iLO 2 Advanced 1.81 at 11:05:47 Jan 15 2010
Server Name: myserver.mydomain.com
Server Power: On

hpiLO-> cd /Map1
status=0
status_tag=COMMAND COMPLETED

/Map1

hpiLO-> reset
status=0
status_tag=COMMAND COMPLETED
Resetting iLO.

CLI session stopped

[Mar 6, 2011]HP Integrated Lights-Out 3 (iLO 3) - Firmware CD Supplemental Update - Online ROM Flash Component for Linux

Type: Firmware - Lights-Out Management
Version: 1.28 (6 Mar 2012)

Products: HP ProLiant DL Servers, HP ProLiant BL Server Blades, HP ProLiant Scalable Systems, HP ProLiant ML Servers, Insight Control Software
OS: Windows,Linux,Other Legacy OS

Description: This component provides updated iLO firmware that can be installed directly on supported Linux Operating Systems. This component can also be used to obtain the firmware image for updating via iLO user interface, utilities, or through the scripting...

Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.

  • iLO 3 web server might run out of SSL sessions. This situation might occur if client opens HTTPS connection to iLO 3 but never does the SSL handshake and keeps the TCP session open forever.
  • iLO 3 might disconnect SSH session when using 'ServerAliveInterval' option.
  • VSP session was restricted to a maximum of 100 characters when pasting text. The limit is now increased to 250 characters.
  • iLO 3 might fail to resolve DNS name, if DNS server replies via TCP with a large number of records (100 or more).
  • iLO 3 might reject subsequent power ON requests from the OA when the following conditions exist within an enclosure:
    • AC power restored to an enclosure where a blade server was auto-powered ON
    • When the blade server was manually powered off via the OA
  • When an SSH certificate was for an Administrator account, it could not be imported via XML.
  • iLO 3 ROM-Based Setup Utility (RBSU) might display 'Resetting iLO, please wait' for 10 minutes after exiting iLO RBSU with changes that cause iLO 3 to reset.
  • iLO 3 web GUI doesn't show 'Drives' information for a second SAS expander in the HP DL385 G7 server.
  • iLO 3 might become slow to respond after closing SSH session.
  • CLI via SSH might lock up after very quickly typing in commands.
  • Unable to generate Certificate Signing Request (CSR) after iLO 3 DNS name was changed.
  • Spurious over- temperature readings were seen in HP DL580 G7 and DL980 G7 servers.
  • Improper value displayed in Power Meter when the server is OFF.
  • Could not install Solaris 10 though Virtual Media.
  • Web GUI might stop responding when SSO login contains key larger than 1024 bits.
  • Could not change Gateway address.
  • The User Administration page exhibited a script vulnerability.

Recommended Links

Google matched content

Softpanorama Recommended

Top articles

Sites

  • HP Integrated Lights-Out 3 v 1.26 Release Notes

    The HP ProLiant Integrated Lights-Out 3 v 1.00 User Guide and the HP ProLiant Integrated Lights-Out

    3 v 1.00 Scripting and Command Line Guide are on the HP website at: http://www.hp.com/go/

    ilo. Select Documentation, and find the latest version of the manuals under the User Guide heading.

Random Findings

iLO 2

Ilo 4 Firmware

  • With iLO 2, remcons is not available you may use the Virtual Serial Port (VSP) to access a text console.
  • To access the VSP, login to iLO 2 via ssh and type vsp.
  • The default Virtual Serial Port is COM 2 IRQ3 IO: 2F8H-2FFh (at least on an HP ProLiant DL360 G5).

You will have to start an agetty process on the COM2 port in order to use the VSP. RHEL 5 example:

Ilo
  • Add the following to /etc/inittab:
  • Run telinit q to have init reread /etc/inittab.

In order to see the startup/shutdown messages on the VSP, add the following to the appropriate kernelline in /boot/grub/menu.lst:

OpenSSH problems with iLO ssh server

The OpenSSH client on my Ubuntu 7.10 system is incompatible with the ssh server on an iLO system with 1.91 firmware. There may be problems with other OpenSSH/iLO versions.

As a workaround, use PuTTY.

Using Virtual Media with the Command-Line Interface

The iLO 2 Virtual Media Java applet does not work well over a low-speed WAN[1]. My Linux ISOs would routinely not boot when using this Java applet.

As an alternative, ISOs may be loaded from an HTTP server using Virtual Media with the iLOcommand-line interface.

Example:

You will likely want to start a Remote Console via the iLO 2's HTTPS interface.

Virtual Power Options

FromHP Integrated Lights-Out 2 User Guide for Firmware 1.35:

  • Momentary Press button provides behavior identical to pressing the physical power button.
  • Press and Hold is identical to pressing the physical power button for five seconds and then releasing it. This option provides the ACPI-compatible functionality that is implemented by some operating systems. These operating systems behave differently depending upon a short press or long press. The behavior of this option might circumvent any graceful shutdown features of the operating system.
  • Cold Boot of the system immediately removes power from the system. The system will restart after approximately six seconds. This option is not available when the server is powered down. This option circumvents graceful operating system shutdown features.
  • Reset System initiates a system reset. This option is not available when the server is powered down. The behavior of this option might circumvent any graceful shutdown features of the operating system.

Hp Ilo 3 Firmware 1-269 Area Code

Retrieved from 'http://brandonhutchinson.com/wiki/ILO_Notes'

How to login from serial port under Linux

Environment: Linux server A with at least one com port which is com1
Objective: enable login through com1 using null modem cable from another machine B which can be Windows or Linux.

Steps:

1. connect null modem cable between A and B at com1 port
2. on Linux server A, vi /etc/inittab and append the followin line:

s0:2345:respawn:/sbin/agetty 115200 ttyS0 vt100

3. If machine B is Linux, use minicom to configure the serial port speed as 115200, then connect
4. If machine B is Windows, use putty to directly connect to serial port, set speed as 115200, then login

note:

for HP Proliant DL serial servers, you can also use VSP (Virtual Serial Port) with ILO2, you can basically ssh into ILO IP address with Administrator login. Add the following lines to /etc/inittab

sx:2345:respawn:/sbin/agetty 115200 ttyS1 vt100

then run 'init q' to enable it, after that, you can use vsp command to connect to this serial port login.

FAQ:

1. how to change speed? - best practise.
vi /etc/inittab , for example, change 115200 to 9600, then comment out the line first, run 'init q' to re-read file, after that, uncomment it, issue 'init q' again.

2. how to enable root login through serail port?
Just add ttyS0 or ttyS1 into /etc/securetty.

3. How to use HP virtual serial port(VSP) to login for HP Proliant servers

use ssh connect to ILO ip address:(if there's firewall in between, enable port 22)
for ILO version 1, just run 'REMCONS'.
for ILO2 , type 'vsp' to connect to ttyS0 or ttyS1 to get console screen.

1.26

References:

1. HP Proliant server VSP documentation
http://h20000.www2.hp.com/bc/docs/support/SupportManual/c00263709/c00263709.pdf

2. Redhat knowledgebase

How do I set up a serial terminal and/or console in Red Hat Enterprise Linux?

http://kbase.redhat.com/faq/docs/DOC-7213

Useful Commands:
1. setserial -a /dev/ttyS0

Posted by Jephe Wu at 9/24/2009 01:57:00 PM

Labels: console, serial port

Etc

Society

Groupthink : Two Party System as Polyarchy : Corruption of Regulators : Bureaucracies : Understanding Micromanagers and Control Freaks : Toxic Managers : Harvard Mafia : Diplomatic Communication : Surviving a Bad Performance Review : Insufficient Retirement Funds as Immanent Problem of Neoliberal Regime : PseudoScience : Who Rules America : Neoliberalism : The Iron Law of Oligarchy : Libertarian Philosophy

Quotes

War and Peace: Skeptical Finance : John Kenneth Galbraith :Talleyrand : Oscar Wilde : Otto Von Bismarck : Keynes : George Carlin : Skeptics : Propaganda : SE quotes : Language Design and Programming Quotes : Random IT-related quotes : Somerset Maugham : Marcus Aurelius : Kurt Vonnegut : Eric Hoffer : Winston Churchill : Napoleon Bonaparte : Ambrose Bierce : Bernard Shaw : Mark Twain Quotes

Bulletin:

Vol 25, No.12 (December, 2013) Rational Fools vs. Efficient Crooks The efficient markets hypothesis : Political Skeptic Bulletin, 2013 : Unemployment Bulletin, 2010 : Vol 23, No.10 (October, 2011) An observation about corporate security departments : Slightly Skeptical Euromaydan Chronicles, June 2014 : Greenspan legacy bulletin, 2008 : Vol 25, No.10 (October, 2013) Cryptolocker Trojan (Win32/Crilock.A) : Vol 25, No.08 (August, 2013) Cloud providers as intelligence collection hubs : Financial Humor Bulletin, 2010 : Inequality Bulletin, 2009 : Financial Humor Bulletin, 2008 : Copyleft Problems Bulletin, 2004 : Financial Humor Bulletin, 2011 : Energy Bulletin, 2010 : Malware Protection Bulletin, 2010 : Vol 26, No.1 (January, 2013) Object-Oriented Cult : Political Skeptic Bulletin, 2011 : Vol 23, No.11 (November, 2011) Softpanorama classification of sysadmin horror stories : Vol 25, No.05 (May, 2013) Corporate bullshit as a communication method : Vol 25, No.06 (June, 2013) A Note on the Relationship of Brooks Law and Conway Law

History:

Fifty glorious years (1950-2000): the triumph of the US computer engineering : Donald Knuth : TAoCP and its Influence of Computer Science : Richard Stallman : Linus Torvalds : Larry Wall : John K. Ousterhout : CTSS : Multix OSUnix History : Unix shell history : VI editor : History of pipes concept : Solaris : MS DOS : Programming Languages History : PL/1 : Simula 67 : C : History of GCC development : Scripting Languages : Perl history : OS History : Mail : DNS : SSH : CPU Instruction Sets : SPARC systems 1987-2006 : Norton Commander : Norton Utilities : Norton Ghost : Frontpage history : Malware Defense History : GNU Screen : OSS early history

Classic books:

The Peter Principle : Parkinson Law : 1984 : The Mythical Man-Month : How to Solve It by George Polya : The Art of Computer Programming : The Elements of Programming Style : The Unix Hater’s Handbook : The Jargon file : The True Believer : Programming Pearls : The Good Soldier Svejk : The Power Elite

Most popular humor pages:

Manifest of the Softpanorama IT Slacker Society : Ten Commandments of the IT Slackers Society : Computer Humor Collection : BSD Logo Story : The Cuckoo's Egg : IT Slang : C++ Humor : ARE YOU A BBS ADDICT? : The Perl Purity Test : Object oriented programmers of all nations : Financial Humor : Financial Humor Bulletin, 2008 : Financial Humor Bulletin, 2010 : The Most Comprehensive Collection of Editor-related Humor : Programming Language Humor : Goldman Sachs related humor : Greenspan humor : C Humor : Scripting Humor : Real Programmers Humor : Web Humor : GPL-related Humor : OFM Humor : Politically Incorrect Humor : IDS Humor : 'Linux Sucks' Humor : Russian Musical Humor : Best Russian Programmer Humor : Microsoft plans to buy Catholic Church : Richard Stallman Related Humor : Admin Humor : Perl-related Humor : Linus Torvalds Related humor : PseudoScience Related Humor : Networking Humor : Shell Humor : Financial Humor Bulletin, 2011 : Financial Humor Bulletin, 2012 : Financial Humor Bulletin, 2013 : Java Humor : Software Engineering Humor : Sun Solaris Related Humor : Education Humor : IBM Humor : Assembler-related Humor : VIM Humor : Computer Viruses Humor : Bright tomorrow is rescheduled to a day after tomorrow : Classic Computer Humor

The Last but not LeastTechnology is dominated by two types of people: those who understand what they do not manage and those who manage what they do not understand ~Archibald Putt. Ph.D

Copyright © 1996-2018 by Dr. Nikolai Bezroukov. www.softpanorama.org was initially created as a service to the (now defunct) UN Sustainable Development Networking Programme (SDNP) in the author free time and without any remuneration. This document is an industrial compilation designed and created exclusively for educational use and is distributed under the Softpanorama Content License. Original materials copyright belong to respective owners. Quotes are made for educational purposes only in compliance with the fair use doctrine.

Hp Ilo 3 Firmware 1.26 Download

FAIR USE NOTICEThis site contains copyrighted material the use of which has not always been specifically authorized by the copyright owner. We are making such material available to advance understanding of computer science, IT technology, economic, scientific, and social issues. We believe this constitutes a 'fair use' of any such copyrighted material as provided by section 107 of the US Copyright Law according to which such material can be distributed without profit exclusively for research and educational purposes.

This is a Spartan WHYFF (We Help You For Free) site written by people for whom English is not a native language. Grammar and spelling errors should be expected. The site contain some broken links as it develops like a living tree...

You can use PayPal to make a contribution, supporting development of this site and speed up access. In case softpanorama.org is down you can use the at softpanorama.info

Disclaimer:

The statements, views and opinions presented on this web page are those of the author (or referenced source) and are not endorsed by, nor do they necessarily reflect, the opinions of the author present and former employers, SDNP or any other organization the author may be associated with.We do not warrant the correctness of the information provided or its fitness for any purpose.

The site uses AdSense so you need to be aware of Google privacy policy. You you do not want to be tracked by Google please disable Javascript for this site. This site is perfectly usable without Javascript.

Last modified: March 12, 2019